ERNiCu-7

ERNiCu-7 copper-nickel alloy base wire is used for GTAW, GMAW, and submerged-arc welding of monel alloy 400, 404 and k-500, also used for overlaying steel after first applying Layer of 610 nickel.

ERNiCu-7 can be used for dissimilar welding applications using various nickel-copper alloys to nickel200 and to copper-nickel alloys. Because of its good resistance to the corrosive effects of seawater and brackish waters, ERNiCu-7 is widely used in marine applications

Common Names: Oxford Alloy® 60  FM 60  Techalloy 418
Conformances: AWS 5.14, ASME SFA 5.14 Class, UNS N04060

CHEMICAL COMPOSITION(%)

C 

Si 

Mn 

S 

P 

Ni 

≤0.15 

    ≤1.25

   ≤4.0

≤0.015

≤0.02 

62-69 

Al 

Ti 

Fe

Cu

others 

 -

≤1.25 

   1.5-3.0 

   ≤2.5 

Rest 

<0.5

 -

WELDING PARAMETERS

Process 

Diameter

Voltage

Amperage

Shielding Gas

TIG

.035”    (0.9mm)

.045”    (1.2mm)                    

1/16”    (1.6mm)                      

3/32”    (2.4mm)                   

1/8”     (3.2mm)

12-15         

13-16         

14-18         

15-20         

15-20 

60-90          

80-110        

90-130      

120-175    

150-220

100% Argon                         

100% Argon                         

100% Argon                         

100% Argon                         

100% Argon

MIG

.035”     (0.9mm)

.045”     (1.2mm)                  

1/16”     (1.6mm) 

26-29         

28-32         

29-33

150-190    

180-220     

200-250

75% Argon + 25% Helium      

75% Argon + 25% Helium      

75% Argon + 25% Helium

SAW

3/32”     (2.4mm)                    

1/8”      (3.2mm)                   

5/32”     (4.0mm)

28-30         

29-32         

30-33

275-350            

350-450            

400-550

Suitable Flux may be used     

Suitable Flux may be used      

Suitable Flux may be used